Hitachi hitachi series inverter Welding System User Manual


 
14
Using the Front Panel Keypad
Please take a moment to familiarize yourself with the keypad layout shown in the figure
below. The display is used in programming the inverter’s parameters, as well as monitoring
specific parameter values during operation.
Key and Indicator Legend
Items Contents
(1) POWER LED Turns ON (Green) while the inverter is powered up.
(2) ALARM LED Turns ON (Red) when the inverter trips.
(3) Program LED
Turns ON (Green) when the display shows changeable parameter.
Blinks when there is a mismatch in setting.
(4) RUN LED Turns ON (Green) when the inverter is driving the motor.
(5) Monitor LED [Hz] Turns ON (Green) when the displayed data is frequency related.
(6) Monitor LED [A] Turns ON (Green) when the displayed data is current related.
(7) Run command LED Turns ON (Green) when a Run command is set to the operator. (Run key is effective.)
(8) 7-seg LED Shows each parameter, monitors etc.
(9) RUN key Makes inverter run.
(10) STOP/RESET key
Makes inverter decelerates to a stop.
Reset the inverter when it is in trip situation
(11) ESC key
Go to the top of next function group, when a function mode is shown
Cancel the setting and return to the function code, when a data is shown
Moves the cursor to a digit left, when it is in digit-to-digit setting mode
Pressing for 1 second leads to display data of d001, regardless of current display.
(12) Up key
(13) Down key
Increase or decrease the data.
Pressing the both keys at the same time gives you the digit-to-digit edit.
(14) SET key
Go to the data display mode when a function code is shown
Stores the data and go back to show the function code, when data is shown.
Moves the cursor to a digit right, when it is in digit-to-digit display mode
(15) USB connector Connect USB connector (mini-B) for using PC communication
(16) RJ45 connector Connect RJ45 jack for remote operator
1
2
RUN
ESC
STOP
RESET
SET
8888
RUN
Hz
A
PWR
ALM
PRG
(1) POWER LED
(2) ALARM LED
(8) 7-seg LED
(4) RUN LED
(10) STOP/RESET key
(15) USB connector
(3) Program LED
(16) RJ45 connector
(14) SET key
(13) Down key (12) Up key
(11) ESC key
(9) RUN key
(7) Run command LED
(5) Monitor LED [Hz]
(6) Monitor LED [A]