“A” Function Defaults
Func.
Code
Name Description
Run
Mode
Edit
Initial data Units
a156
PID sleep function action
threshold
Sets the threshold for the action,
set range 0.0~400.0 Hz
U
0.00 Hz
a157
PID sleep function action delay
time
Sets the delay time for the
action, set range 0.0~25.5 sec
U
0.0 sec
A161
[VR] input active range start
frequency
The output frequency
corresponding to the analog
input range starting point,
range is 0.0 to 400.0 Hz
U
0.00 Hz
A162
[VR] input active range end
frequency
The output frequency
corresponding to the current
input range ending point,
range is 0.0 to 400.0 Hz
U
0.00 Hz
A163
[VR] input active range start % The starting point (offset) for the
current input range,
range is 0. to 100.%
U
0. %
A164
[VR] input active range end % The ending point (offset) for the
current input range,
range is 0. to 100.%
U
100. %
A165
[VR] input start frequency
select
Two options; select codes:
00Use offset (A161 value)
01Use 0Hz
U
01