Intelligent Terminal Functions
“C” Function Defaults
Func.
Code
Name Description
Run
Mode
Edit
Initial data Units
C001
Input [1] function Select input terminal [1] function,
68 options (see next section)
U
00
[FW]
C002
Input [2] function Select input terminal [2] function,
68 options (see next section)
U
01
[RV]
C003
Input [3] function
[GS1 assignable]
Select input terminal [3] function,
68 options (see next section)
U
02
[CF1]
C004
Input [4] function
[GS2 assignable]
Select input terminal [4] function,
68 options (see next section)
U
03
[CF2]
C005
Input [5] function
[PTC assignable]
Select input terminal [5] function,
68 options (see next section)
U
09
[2CH]
C006
Input [6] function Select input terminal [6] function,
68 options (see next section)
U
18
[RS]
C007
Input [7] function Select input terminal [7] function,
68 options (see next section)
U
13
[USP]
C011
Input [1] active state
U
00
C012
Input [2] active state
U
00
C013
Input [3] active state
U
00
C014
Input [4] active state
U
00
C015
Input [5] active state
U
00
C016
Input [6] active state
U
00
C017
Input [7] active state
Select logic conversion, two option
codes:
00normally open [NO]
01normally closed [NC]
U
00
C021
Output [11] function
[EDM assignable]
U
01
[FA1]
C022
Output [12] function
48 programmable functions
available for logic (discrete) outputs
(see next section)
U
00
[RUN]
C026
Alarm relay function 48 programmable functions
available for logic (discrete) outputs
(see next section)
U
05
[AL]
C027
[EO] terminal selection
(Pulse/PWM output)
13 programmable functions:
00Output frequency (PWM)
01Output current (PWM)
02Output torque (PWM)
03Output frequency (Pulse train)
04Output voltage (PWM)
05Input power (PWM)
06Electronic thermal load ratio
(PWM)
07LAD frequency (PWM)
08Output current (Pulse train)
10Heat sink temperature (PWM)
12General output (PWM)
15Pulse train input monitor
16Option(PWM)
U
07