Hitachi hitachi series inverter Welding System User Manual


 
83
“P” Function Defaults
Func.
Code
Name Description
Run
Mode
Edit
Initial data Units
P072
Position range (Forward)
0 to +268435455(Higher 4-digits
displayed)
+2684354
55
Pulse
s
P073
Position range (Reverse)
–268435455 to 0(Higher 4-digits
displayed)
-2684354
55
Pulse
s
P075
Positioning mode selection
00…With limitation
01…No limitation (shorter route)
P004 is to be set 00 or 01
U
00
-
P077
Encoder disconnection
timeout
0.0 to 10.0 s
1.0
s
p100
~
P131
EzSQ user parameter
U(00) ~ U(31)
Each set range is 0~65535
0.
-
P140
EzCOM number of data 1 to 5
5
-
P141
EzCOM destination 1 adderss 1 to 247
1
-
P142
EzCOM destination 1 register 0000 to FFFF
0000
-
P143
EzCOM source 1 register 0000 to FFFF
0000
-
P144
EzCOM destination 2 adderss 1 to 247
2
-
P145
EzCOM destination 2 register 0000 to FFFF
0000
-
P146
EzCOM source 2 register 0000 to FFFF
0000
-
P147
EzCOM destination 3 adderss 1 to 247
3
-
P148
EzCOM destination 3 register 0000 to FFFF
0000
-
P149
EzCOM source 3 register 0000 to FFFF
0000
-
P150
EzCOM destination 4 adderss 1 to 247
4
-
P151
EzCOM destination 4 register 0000 to FFFF
0000
-
P152
EzCOM source 4 register 0000 to FFFF
0000
-
P153
EzCOM destination 5 adderss 1 to 247
5
-
P154
EzCOM destination 5 register 0000 to FFFF
0000
-
P155
EzCOM source 5 register 0000 to FFFF
0000
-