Hitachi hitachi series inverter Welding System User Manual


 
18
When a function code is shown… When a data is shown…
ESC key Move on to the next function group
Cancels the change and moves back to the
function code
SET key Move on to the data display
Fix and stores the data and moves back to
the function code
U key
Increase function code Increase data value
V key
Decrease function code Decrease data value
Note
Keep pressing for more than 1 second leads to d001 display, regardless the display situation. But note that
the display will circulates while keep pressing the [ESC] key because of the original function of the key.
(e.g. F001 A001 b001 C001 displays 50.00 after 1 second)