TROUBLESHOOTING & REPAIR
F-51 F-51
LN-9 Wire Feeder
FIGURE F.12 – METER PANEL ASSEMBLY SCREWS
MOUNTING SCREWS
METER
DIGITAL METER AND METER PC BOARD REMOVAL AND
REPLACEMENT (continued)
METER PC BOARD REMOVAL
PROCEDURE
1. Remove input power to the LN-9 wire feeder.
2. Locate and remove the two screws on the top
left and right side of the meter panel assem-
bly. See Figure F.12.
FIGURE F.13 – METER REMOVAL (WITH SHORT LEADS)
3. Lift the right side cover assembly. 4. Carefully remove the meter enclosure panel.
Note the limited lead length. See Figure F.13.