ACCESSORIES
C-4 C-4
LN-9 Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
GUN AND CABLE ASSEMBLIES
A variety of standard Lincoln and Magnum gun and
cable assemblies are available for the LN-9 in 10 ft.,
12 ft. and 15 ft. cable lengths. Choose the gun and
cable assembly to suit the LN-9 welding application
and wire size. See Table C-1.
TABLE C.1 – LN-9 GUN AND CABLE ASSEMBLIES
60% Duty
Process Model Electrode Rating
Gas Metal Arc Welding K497
(1)
.025-.045” (0.6-1.14 mm) solid 200 amps
200 amps
K498
(2)
.025-.045” (0.6-1.14 mm) solid 200 amps
200 amps
Magnum K470
(1)
.035-
5
64” (0.9-2.0 mm) solid 300 amps
300 amps
Magnum K471
(1)
.035-
5
64” (0.9-2.0 mm) solid 400 amps
400 amps
Magnum K478
(2)
.035-
5
64” (0.9-2.0 mm) solid 300 amps
300 amps
Magnum K479
(2)
.035-
5
64” (0.9-2.0 mm) solid 400 amps
400 amps
Innershield
®
K126 .062-
3
32” (1.6-2.4 mm) Innershield 350 amps
K115-120 for .120” and
7
64” (3.0 and 2.8 mm) 450 amps
K115-3/32 for
3
32” (2.4 mm) 450 amps
K115-5/64 for .068-
5
64” (1.7-2.0 mm) 450 amps
K116-120 for 120” and
7
64” (3.0 and 2.8 mm) 600 amps
K116-3/32 for
3
32” (2.4 mm) 600 amps
K206
(3)
.062-
3
32” (1.6-2.4 mm) Innershield 350 amps
K289
(3)
.068-.120” (1.7-3.0 mm) lnnershield 500 amps
K309
(3)
.062-
3
32” (1.6-2.4 mm) lnnershield 250 amps
Submerged Arc K112
1
16” (1.6 mm) solid 500 amps
K113-1
5
64” (2.0 mm) 600 amps
K113-2
3
32” (2.4 mm) 600 amps
K-114
3
32 or
5
64” (2.4 or 2.0 mm) solid 600 amps
(1)
K466-1 connector kit required.
(2)
K489 Fast-Mate™ Adapter required.
(3)
Linconditioner™ guns are recommended for locations where smoke accumulation is a problem and conven-