Test Meter PC Board Accuracy. (Metric Models Only)
1. Use a test meter with at least 3-1/2 digits and +/-
.5% accuracy.
2. Connect the + probe to lead called for in the table
below and the - probe to lead #510C.
NOTE: The coating will have to be removed from the
test points.
3. With the meter in SET M/MIN, adjust the speed con-
trol until the LN-9 meter matches the settings in the
table below. If the test meter does not match the
readings, the meter PC board may be faulty.
Replace the meter PC board.
TROUBLESHOOTING & REPAIR
F-41 F-41
LN-9 Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
METER CIRCUIT ACCURACY TEST (continued)
METRIC MODEL METRIC RANGE SET M/MIN READING TEST VOLTMETER
READING
LN-9 or LN-9F LO 8.89 LEAD #560
3.50 +/-.05VDC
HI 15.2 LEAD #561
6.00 +/-.07VDC
LN-9H or LN-9FH LO 8.28 LEAD #560
2.00 +/- .05VDC
HI 24.8 LEAD #561
6.00+/-.07VDC