Lincoln Electric SVM127-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-40 F-40
LN-9 Wire Feeder
METER CIRCUIT ACCURACY TEST (continued)
Test Digital Meter Accuracy. (For LN-9 models
above code 7980 with separable digital meter and
meter boards only).
1. Use a test meter with at least 3-1/2 digits and
+/- .5% accuracy.
2. Connect the + probe to TP4 and the - probe to
lead #510C.
NOTE: The coating will have to be removed from
the test points.
3. With the meter in SET volts, adjust the voltage
control until the test meter matches the set-
tings in the table below.
If the LN-9 digital meter does not match the
readings, the LN-9 digital meter may be faulty.
Replace the digital meter.
LN-9 SET VOLTS READING TEST VOLTMETER READING
15.0 V .150 +/- .004 VDC
30.0 V .300 +/- .004 VDC
60.0 V .600 +/- .006 VDC
Test Meter PC Board Accuracy. (All Models)
1. Use a test meter with at least 3-1/2 digits and
+/- .5% accuracy.
2. Connect the + probe to leads #517 and the -
probe to lead #510C.
NOTE: The coating will have to be removed from
the test points.
3. With the meter in SET volts, adjust the voltage
control until the LN-9 meter matches the set-
tings in the table below.
If the test meter does not match the readings, the
meter PC board may be faulty. Replace the
meter PC board.
LN-9 SET VOLTS READING TEST VOLTMETER READING
15.0 V 1.50 +/- .05 VDC
30.0 V 3.00 +/- .05 VDC
60.0 V 6.00 +/- .07 VDC
Test Meter PC Board Accuracy. (For LN9-H,
LN-9FH Models Only)
1. Use a test meter with at least 3-1/2 digits and
+/- .5% accuracy.
2. Connect the + probe to lead #519 and the -
probe to lead #510C.
NOTE: The coating will have to be removed from
the test points.
3. With the meter in SET IN/MIN, adjust the
speed control until the LN-9 meter matches
the settings in the table below. If the test
meter does not match the readings, the meter
PC board may be faulty. Replace the meter
PC board.
LN-9 SET IN/MIN READING TEST VOLTMETER READING
082 IPM 0.50 +/- .05 VDC
49 IPM 3.00 +/- .05 VDC
978 IPM 6.00 +/- .07 VDC