MLIM-8; DIGITAL I/O INTERFACE MODULE OVERVIEW
Overview:
The MLIM-8 is an eight channel Interface Module for use in the OMP-MODL
System Base. Each of the eight channels can be individually programmed
for any combination of Event input or Digital output via the HyperWare
software (HyperNet).
Module Installation:
Refer to the Installation Section earlier in this chapter for detailed installation
instructions of the Interface Module onto the System Base.
I/O Module Layer Requirements / Limitations:
The MLIM-8 module can be installed in any of the five I/O Module positions
(Figure 3... -4). The module layer address must be set on the module to
correspond to the layer position into which the module is installed.
This address is programmed into the module through the use of the Module
Address Switch bank (Figure 3... -31). The switch bank contains 5 switches.
Note the marking on the circuit board identifying address rows for Module
Layers 2 through 5. Set one switch in the bank ON corresponding to a
module layer determined above. The switch bank should have only ONE
switch ON and the other four switches OFF.