A SERVICE OF

logo

6 – 5
6.4 An Error Message Was Displayed
Symptom Cause Solution
CURRENT LIMIT or POSI-
TION ALARM is displayed.
The STATUS lamp flickers.
The cutting conditions are not suitable for the
medium being cut.
Reduce the cutting speed.
Reduce the cutting force (see
“3.3 Setting the Cutter-Pen
Conditions”).
Excessive load is causing the current to the
motor to exceed the rated value.
Remove the obstruction and
turn the cutting plotter back
on.
The pen carriage movement is being
obstructed.
The pen carriage was subjected to external
pressure during cutting.
Scraps of the medium in the moving parts are
impeding operation.
If this problem occurs frequently, contact your sales representative or nearest
Gerber distributor.
SPEED ERROR is displayed.
The STATUS lamp flickers.
The pen carriage was subjected to external
pressure after the power was turned on.
Turn the cutting plotter off
and then back on again.
The internal speed control is faulty.
If this problem occurs frequently, contact your sales representative or Gerber
Service.