GBC F - 160 CE Laminate Trimmer User Manual


 
Page 3 - 3
SpecificationsF - 160 CE Operation and Maintenance Manual
© GBC Films Group April 2000
Job save:
Roll design:
Section 3.4 Electrical
United Statesand Canada:
Europe:
B.T.U. output:
Heater wattages:
Amperage draw:
D/C voltage used:
A/C voltage used:
• Save up to 9 job parameters
• High release silicone rolls
230 - 240 VAC, 50/60 Hz, single phase, 55 amps.
230 - 240 VAC, Wye 3 phase, 32 amps/ phase
• 31,732 B.T.U. / hour
• 5600 watts per heater
• No heat, motor only : 1 - 3 amps
• Top heat and motor : 20 - 23 amps
• Both heat and motor : 40 - 43 amps
• 24 vdc
• 12 vdc isolated x 2
• 24 vdc isolated
• 230 vac ( minimum )