Page 4 - 23
InstallationF - 160 CE Operation and Maintenance Manual
© GBC Films Group April 2000
4.11 Function check
The function check ensures that the laminator
functions properly when operating. This check is
recommended before performing any applications.
If a step that does not react according to the
description, call your local area service representative
immediately.
WARNING
Do not wear ties, loose fit clothing or
dangling jewelry while operating or
servicing the laminator. These items can get
caught in the nip and choke you or you can
be crushed or burned.
4.11.1 Control panel
a) Press TOP TEMP. ▲ to a value of 120
o
F
( 48
o
C ). TOP TEMP DISPLAY begins
flashing.
120 68
TOP TEMP BOT TEMP
-
b) Press BOT TEMP ▲ to a value of 120
o
F
( 48
o
C ). BOT TEMP DISPLAY begins
flashing.
120 120
TOP TEMP BOT TEMP
--
c) SEL can not be tested until you have saved
parameters within a JOB location. Refer to
Section 5.4 Job programming for SEL and
SAV.
= Flashing
JOB
STANDBY
SAV
0
SEL
d) Press GAP ▼ once. GAP DISPLAY
decreases 1/16th of an inch per press. The
upper main roller moves accordingly. Once to
“0”, the upper main roller is contacting the
lower main roller.
1-0
GAP
PRESSURE