RuggedCom RS400 Welder User Manual


 
Ethernet Ports
RS400 107 ROS™ v3.5
Figure 76: EoVDSL Parameters Form
Port
Synopsis: 1 to maximum port number
Default: Depends on the particular product (3 for RS920L, 7 for RS930L, 9 for RS9XX, etc.)
The port number as seen on the front plate silkscreen of the switch.
Type
Synopsis: { Univ, LR }
The type of VDSL port. Supported types: Universal and Long Reach.
Mode
Synopsis: { Master, Slave }
Default: Master
Specify if the port should operate as a VDSL Master or Slave. Note that for Long-reach VDSL
port, “Mode” is pre-determined by hardware and cannot be changed by user.
Set Rate (DS/US)
Synopsis (Universal VDSL):
{ Auto, 35.2/35.2 Mbs, 30.2/30.2 Mbs, 25.3/25.3 Mbs, 20.1/20.1 Mbs, 15.4/15.4 Mbs, 10.1/10.1
Mbs, 5.1/5.1 Mbs, 2.7/2.7 Mbs, 1.2/1.2 Mbs }
Synopsis (Long-reach VDSL):
{ Auto, 40.0/20.3 Mbs, 25.3/5.1 Mbs, 20.1/0.5 Mbs, 15.2/0.5 Mbs, 10.1/0.5 Mbs, 5.1/0.5 Mbs,
2.2/0.5 Mbs, 1.2/0.5 Mbs, 0.5/0.2 Mbs }
Default: Auto
Specify required down-stream (Master-to-Slave) and up-stream (Slave-to-Master) bit rate.
If this parameter is set to 'Auto', the system will automatically find the highest rate supported for