Default: 11800
A threshold for the sampled variable. When the current sampled variable value is greater than
or equal to this threshold, and the value at the last sampling interval was less than this
threshold, a single event will be generated. A single event will also be generated if the first
sample after this record is created is greater than or equal to this threshold and the associated
startup alarm is equal to 'rising'. After rising alarm is generated, another such event will not be
generated until the sampled value falls below this threshold and reaches the value of
FallingThreshold.
Falling Thr
Synopsis: 0 to 2147483647
Default: 11790
A threshold for the sampled variable. When the current sampled variable value is less than or
equal to this threshold, and the value at the last sampling interval was greater than this
threshold, a single event will be generated. A single event will also be generated if the first
sample after this record is created is less than or equal to this threshold and the associated
startup alarm is equal to 'falling'. After falling alarm is generated, another such event will not be
generated until the sampled value rises above this threshold and reaches the value of
RisingThreshold.
Value
Synopsis: 0 to 2147483647
The value of monitoring object during the last sampling period. The presentation of value
depends of sample type ('absolute' or 'delta').
Type
Synopsis: { absolute, delta }
Default: delta
The method of sampling the selected variable and calculating the value to be compared against
the thresholds. The value of sample type can be 'absolute' or 'delta'.
Interval
Synopsis: 0 to 2147483647
Default: 5
The number of seconds in over which the data is sampled and compared with the rising and
falling thresholds.
Startup Alarm
Synopsis: { rising, falling, risingOrFalling }
Default: risingOrFalling
The alarm that may be sent when this record is first created if condition for raising alarm is met.
The value of startup alarm can be 'rising', 'falling' or 'risingOrFalling'
Rising Event
Synopsis: 0 to 65535
Default: 1
The index of the event that is used when a falling threshold is crossed. If there is no
corresponding entry in the Event Table, then no association exists. In particular, if this value is
zero, no associated event will be generated.
Falling Event
Synopsis: 0 to 65535
Default: 1
The index of the event that is used when a rising threshold is crossed. If there is no