14.3.6 Using RSH and SQL
Combination of remote shell scripting and SQL commands offers a means to interrogate and
maintain a large number of devices. Consistency of configuration across sites may be verified
by this method. The following presents a simple example where the devices to interrogate are
drawn from the file “Devices”.
Figure 189 Using RSH and SQL
C:> type Devices
10.0.1.1
10.0.1.2
10.0.1.3
c:\> for /F %i in (devices) do rsh %i -l admin,admin sql select from ethportcfg
where flow_control = disabled
C:\>rsh 10.0.1.1 -l admin,admin sql select from ethportcfg where flow_control =
disabled
Port Name Status Media Type Flow Control FEFI Link Alarms
5 Port 5 Enabled Auto Select Disabled Disabled Enabled
1 records selected
C:\>rsh 10.0.1.2 -l admin,admin sql select from ethportcfg where flow_control =
disabled
0 records selected
C:\>rsh 10.0.1.3 -l admin,admin sql select from ethportcfg where flow_control =
disabled
Port Name Status Media Type Flow Control FEFI Link Alarms
3 Port 3 Enabled Auto Select Disabled Disabled Enabled
7 Port 7 Enabled Auto Select Disabled Disabled Enabled
8 Port 8 Enabled Auto Select Disabled Disabled Enabled
13 Port 13 Enabled Auto Select Disabled Disabled Enabled
4 records selected
C:\