RuggedCom RS400 Welder User Manual


 
Serial Protocols
ROS™ v3.5 78 RS400
TIN Mode:
Synopsis: 1 to 2
Default: 1
TIN Protocol running mode.
TIN Transport:
Synopsis: { TCP, UDP }
Default: UDP
The network transport used to transport protocol data over IP network.
WIN Transport:
Synopsis: { TCP, UDP }
Default: UDP
The network transport used to transport protocol data over IP network.
TIN IP Port
Synopsis: 1024 to 65535
Default: 51000
The local port number on which TIN protocol listens for TCP connections or UDP datagrams.
WIN IP Port
Synopsis: 1024 to 65535
Default: 52000
The local port number on which WIN protocol listens for TCP connections or UDP datagrams.
Message Aging Timer
Synopsis: 1 to 3600 or { Disabled }
Default: Disabled
This timing parameter (in seconds) is used to configure the removal of duplicate messages in
TIN mode2. If the same message is received within the time interval specified by this parameter,
the new message is considered duplicate, and is thus discarded.
Address Aging Timer
Synopsis: 60 to 1000
Default: 300 s
The time of communication inactivity after which a learned TIN address is removed from the
device address table. Entries in Link Statistics Table with the aged address will be kept until
statistics are cleared.
Broadcast Addresses
Synopsis: { Static, Dynamic, StaticAndDynamic }
Default: Static
A The device address table in which addresses will be found for broadcast messages.
Unicast Addresses
Synopsis: { Static, Dynamic, StaticAndDynamic }
Default: Dynamic
A The device address table in which addresses will be found for unicast messages.
Link Stats
Synopsis: { Disabled, Enabled }
Default: Enabled
Enables links statistics collection for protocol.