Agilent Technologies N6700 Welding System User Manual


 
1 Quick Reference
18 Series N6700 User’s Guide
SCPI Command Description
TRIGger
:ACQuire (Acquire commands only on Agilent N6761A/62A and Option 054)
[:IMMediate] (@chanlist) Triggers the measurement immediately
:SOURce BUS | PIN<n> | TRAN<n>, (@chanlist) Sets the measurement trigger source
:TRANsient
[:IMMediate] (@chanlist) Triggers the output immediately
:SOURce BUS | PIN<n> | TRAN<n>, (@chanlist) Sets the output trigger source
Common Commands
Command Description Command Description
*CLS Clear status *RST Reset
*ESE <NRf> Standard event status enable *SAV <NRf> Saves an instrument state
*ESR? Return event status register *SRE <NRf> Set service request enable register
*IDN? Return instrument identification *STB? Return status byte
*OPC Enable "operation complete" bit in ESR *TRG Trigger
*OPT? Return option number *TST? Performs self-test, then returns result
*RCL <NRf> Recalls a saved instrument state *WAI Pauses additional command processing
*RDT? Return output channel descriptions until all device commands are done
*RST Settings
These settings are set by the *RST (Reset) command
CAL:STAT OFF OUTP:PMOD VOLT
[SOUR:]CURR 0.08 or MIN OUTP:PROT:COUP OFF
[SOUR:]CURR:MODE FIX OUTP:PROT:DEL 0.02
[SOUR:]CURR:PROT:STAT OFF OUTP:REL:POL NORM
[SOUR:]CURR:RANG MAX [SOUR:]POW:LIM MAX
[SOUR:]CURR:TRIG MIN SENS:CURR:RANG MAX
[SOUR:]DIG:OUTP:DATA 0 SENS:FUNC “VOLT”
DISP:VIEW METER1 SENS:SWE:POIN 1024
INIT:CONT:TRAN OFF SENS:SWE:OFFS:POIN 0
[SOUR:]LIST:COUN 1 SENS:SWE:TINT 20.48E6
[SOUR:]LIST:CURR MIN SENS:VOLT:RANG MAX
[SOUR:]LIST:DWEL 0.001 SENS:WIND RECT
[SOUR:]LIST:STEP AUTO [SOUR:]STEP:TOUT FALSE
[SOUR:]LIST:TERM:LAST OFF TRIG:ACQ:SOUR BUS
[SOUR:]LIST:TOUT:BOST OFF TRIG:TRAN:SOUR BUS
[SOUR:]LIST:TOUT:EOST OFF [SOUR:]VOLT MIN
[SOUR:]LIST:VOLT MIN [SOUR:]VOLT:MODE FIX
OUTP OFF [SOUR:]VOLT:PROT MAX
OUTP:DEL:FALL 0 [SOUR:]VOLT:RANG MAX
OUTP:DEL:RISE 0 [SOUR:]VOLT:SLEW 9.9E+37
[SOUR:]VOLT:TRIG MIN