Output On/Off sequencing A turn-on/turn-off delay capability for each output allows output on/off
sequencing.
Remote voltage sensing Two remote sensing terminals are provided for each output. When shipped,
the remote sense jumpers are included in a separate bag. See Chapter 2.
Voltage and current
measurements
All power modules can measure their own output voltage and current.
Voltage, current, and
temperature protection
Each output has over-voltage, over-current, and over-temperature
protection. Over-voltage and over-current protection are programmable.
When activated, the protection circuits cause the voltage to go to zero, the
output to be disabled, and the protection status to be reported.
System Features
SCPI language The instrument is compatible with the Standard Commands for
Programmable Instruments (SCPI).
Choice of three interfaces GPIB (IEEE-488), LAN, and USB remote programming interfaces are built in.
Front panel I/O setup Menus let you set up GPIB and LAN parameters from the front panel. Refer
to Chapter 3 for details.
Built-in Web server A built-in Web server lets you control the instrument directly from an
internet browser on your computer. Refer to Chapter 3 for details.
Real-time status
information
The front panel indicates the status of each output. It also indicates when
a protection shut-down has occurred.
Module identification Each module has identifying data stored in non-volatile memory.
Information includes model number, serial number, and options. This
information can be displayed on the front panel.
Model Differences
Feature DC Power Modules Autoranging Modules Precision Modules
N6731B -
N6736B
N6741B -
N6746B
N6773A -
N6776A
N6751A N6752A N6753A
N6754A
N6761A N6762A
Output power rating 50 W 100 W 300 W 50 W 100 W 300 W 50 W 100 W
Autoranging output capability NO NO NO YES YES YES YES YES
Precision output and measurement capability NO NO NO NO NO NO YES YES
Low voltage output and measurement range NO NO NO NO NO NO YES YES
Low current output and measurement range NO NO NO NO NO NO YES YES
Simultaneous voltage and current measurement NO NO NO NO NO NO YES YES
100 microampere measurement range NO NO NO NO NO NO Option Option
Output list capability (Test Extensions) NO NO NO Option Option Option YES YES
Array readback capability (Test Extensions) NO NO NO Option Option Option YES YES
Programmable sample rate (Test Extensions) NO NO NO Option Option Option YES YES
Double-wide NO NO NO NO NO YES NO NO