Agilent Technologies E6385A Router User Manual


 
Installation
Connecting the PC to the Test Set and the MSC
Chapter 2
O:\Manuals\E6385A_Cdma\Book\Install.fm
32
Connecting the PC to the Test Set and the MSC
The following sections describe the processes for connecting the PC to both the Test Set
and the MSC.
Connecting the PC to the Test Set
Connect a null modem cable (DB9 to DB9) from the Test Set to the COM port of the PC
as shown in Figure 2-6.
Figure 2-6 Test Set to PC and PC to MSC Connection
At this point, you should be able to communicate with the Test Software.
To test the connection, configure the test set as follows, then attempt a screen capture.
NOTE
The screen capture function is inoperable while the Test Software is running. The Test
Software must be paused.
Step 1. If the Test Software is running (a star appears in the upper right-hand corner of the
display), press the
Pause/Continue key to pause it.
Step 2. Press the Test Set
Shift key. then the Inst Config (I/O Config) key. The Test Set will display
the I/O CONFIGURE screen.
Step 3. Select the Serial_9 In field and press the knob to toggle the setting to Inst
(underlined).
Step 4. Press the Test Set
Shift key, then the Print (Printer Config) key. The Test Set will display
the PRINTER CONFIGURE screen.
Step 5. Select the Model field and select DeskJet from the drop-down Choices: list.
MSC
Phone Line
Laptop PC
Test Set Side Panel
or
LAN Connection
COM DB9
Connector
Null Modem Cable
DB9 Connector
SERIAL 9
SERIAL 10
SERIAL 11
SERIAL 9 Port