Agilent Technologies E6385A Router User Manual


 
Performing Tests
Automated BBA Test
Chapter 4
67
Performing Tests
Select and Run the Test
Perform the Automated BBA Test as follows:
Step 1. From the Lucent CDMA Tests Main Menu screen, select the Test Selections field. The
Test Software will display the Test Selections Menu screen.
Step 2. Select the Automated BBA Test field.
Step 3. Follow the displayed instructions and diagram as prompted to make the measurement.
NOTE This procedure might include steps that prompt you to disconnect cables from the site
antenna ports and make connections to the Test Set. Before removing or re-installing the
antenna cables, make certain that the transmitter has been turned off by the MSC (or by
switch personnel if not using a modem). The green ACT LEDs on the ACU and BCR
modules should be off.
Review the Results
The Test Software will begin running tests on the active BBA. See Figure 4-6. As tests
are performed, test results will begin showing on the display with a failure indication if a
measurement falls outside the specified limits.
If you wish to stop testing before the sequence is complete, press the
k5 (Abort) key.
Depending on the state of the system, it might take as long as 60 seconds to stop the test.
Because the site configuration might not have been reset before testing was aborted, the
Test Software will offer a choice to send a “multistop” command to reset the BBAs.
Figure 4-6 Partial Code Domain Tests Sequence Results