Changing Pass/Fail Limits
Pass/Fail limits define the values with which a measurement result is compared to
determine if the Base Station under test meets the specified standards. Default values
are set in the Test Software. These default values may be changed to suit particular
requirements.
Press the
Menu key, then select the Spec Pass/Fail Limits field to display the TESTS
(Pass/Fail Limits) screen (see Figure 5-9).
The fields in the TESTS (Pass/Fail Limits) screen allow you to change the pass/fail limits
to optimize the testing conditions (see Figure 5-10 and Figure 5-11). For information on
saving customized pass/fail limits, see “Saving/Deleting a Procedure” on page 101.
Figure 5-9 TESTS (Pass/Fail Limits) Screen
NOTE The TESTS (Pass/Fail Limits) screen might not be used in the particular Test Software
package that you are using, or some fields might not be present, depending on the Test
Software application. The message “Access to secure test information denied” will be
displayed if the screen is not supported in the Test Software package.
Selects the limit(s) with which
to compare measured results.
Choices includes Upper,
Lower, and Both.
The descriptions for
the Test Software
might be different
than shown here.
Selects the pass/fail
limit to be edited.
Sets the lower or upper
pass/fail limits.