Agilent Technologies E6385A Router User Manual


 
Performing Tests
Code Domain Analyzer Test
Chapter 4
O:\Manuals\E6385A_Cdma\Book\perf-tst.fm
70
Code Domain Analyzer Test
This test sets up the Test Software to make manual measurements on a CDMA
transmitter. This test is useful if you wish to switch between Code Domain Power, Code
Domain Timing, and Code Domain Phase measurement screens. It is also useful for
examining changes in Code Domain readings over time. Otherwise, it would probably be
better to use the automated tests: “Code Domain Tests” on page 64 and “Automated
BBA Test” on page 66.
Available measurements in the Code Domain Analyzer screen are:
Code Domain Power
Code Domain Timing
•Code Domain Phase
Parameters and Specifications Used
The following specifications and parameters are used when running this test. See
Chapter 5, “Reference,” for descriptions of the specifications and parameters.
Parameters:
None used for this test.
Specifications (Pass/Fail Limits):
None used for this test.
Select and Run the Test
Perform code domain analyzer measurements as follows:
Step 1. From the Lucent CDMA Tests Main Menu screen, select the Test Selections field. The
Test Software will display the Test Selections Menu screen.
Step 2. Select the Code Domain Analyzer field.
Step 3. Follow the displayed instructions and diagram to make the measurement.
NOTE This procedure might include steps that prompt you to disconnect cables from the site
antenna ports and make connections to the Test Set. Before removing or re-installing the
antenna cables, make certain that the transmitter has been turned off by the MSC (or by
switch personnel if not using a modem). The green ACT LEDs on the ACU and BCR
modules indicate the transmitter is active, and therefore should be off before
disconnecting cables.