Agilent Technologies E6385A Router User Manual


 
Installation
Configuring the Test Software
Chapter 2
O:\Manuals\E6385A_Cdma\Book\Install.fm
42
Step 7. Select the Specified Output Power [Watts] field, turn the knob to the expected
output power at the TX Antenna port (foam jumper) or at the Base Station TX Test Port
after subtracting the coupling factor, and press the knob to enter it. This value must be
set for both manual and automated testing.
NOTE
This output power setting is for a pilot channel only signal. It is affected by: 1) the
number of channel elements that are active, and 2) the BCR attenuation setting and
digital gain unit (DGU) settings for the pilot, sync, paging, and traffic channels in the
translation table. Use the value specified by Lucent for testing power.
Step 8. Select the RF Channel Standard field and select from the drop-down Choices: list the
standard to be used when you enter a channel number: N. American Cellular,
N. American PCS, or Korean PCS P4.
Step 9. Select the Channel Number field, rotate the knob to the number for the CDMA channel
on which the Base Station is transmitting, and press the knob to select it.
Step 10. Select the PN Offset field, rotate the knob to the value for the cell site, and press the
knob to enter it. If you are uncertain of the offset, run the “PN Offset Search Test” on
page 79) to find and enter the number automatically.
Step 11. Select the Send Control Commands to MSC field.
If you wish to use automated control of the cell site, press the knob to toggle it to YES. If
you toggle it to YES, the Channel Elements to Test field will appear on the next line.
Rotate the knob to the desired number between 0 and 55, and press the knob to select it;
or use the DATA ENTRY keys to enter the number and either press the knob or press
the
Enter key.
If you wish to use manual control of the cell site, press the knob to toggle it to No.
Step 12. Press the