Lincoln Electric SVM120-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-8 A-8
RANGER 10-LX
LOAD
230 Volt
60 Hz.
3-Wire
Service
230 VOLT
GROUNDED CONDUCTOR
115 VOLT
115 VOLT
POWER
COMPANY
METER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
40 AMP
230 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
230 VOLTS
GND
N
50 AMP, 115/230
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 115/230 VOLT
RECEPTACLE
NOTE: No. 8 COPPER CONDUCTOR CABLE
SEE NATIONAL ELECTRIC CODE FOR
ALTERNATE WIRE SIZE RECOMMENDATIONS.
NEUTRAL
BUS
FIGURE A.2 - CONNECTION OF RANGER 10-LX TO PREMISES WIRING
45 AMP
NOTE: No. 6 COPPER 4 CONDUCTOR CABLE.
SEE NATIONAL ELECTRIC CODE FOR
ALTERNATE WIRE SIZE RECOMMENDATIONS.
SYSTEM
EARTH
GROUND
PER THE U.S.
NATIONAL
ELECTRICAL
CODE
50 AMP, 115/230 VOLT
RECEPTACLE
LOCATED ON
FRONT OF MACHINE