Lincoln Electric SVM120-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
RANGER 10-LX
TECHNICAL SPECIFICATIONS - RANGER 10-LX
INPUT - DIESEL ENGINE
Manufacturer Description Speed Displacement Ignition Capacities
KUBOTA 3 cyl., 3600 RPM 52.17 cu. in. Electric Fuel: 10 gal. (38 l)
DH850B-88 liquid-cooled Full load (855 cc)
diesel Oil: 3.9 qt. (3.7 l)
23 HP @ 3750 RPM
3600 RPM High idle
Cooling system:
2150 RPM 5.4 qts. (5.1 l)
Low idle
RATED OUTPUT - WELDER
Duty Cycle Amps Volts at Rated Amperes
100% Duty Cycle 250 AC Constant Current 25
100% Duty Cycle 250 DC Constant Current 25
100% Duty Cycle 250 DC Constant Voltage 30
OUTPUT - WELDER AND GENERATOR
Auxiliary Power for
Welding Ranges Max. Open Circuit Voltage Auxiliary Power
(1)
Wire Feeders
45- 250 Amps 80 Volts RMS 10000 Continuous Watts 42V, 60 Hz, 8 Amps
@ 3700 RPM 87 Amps @ 115 V
43.5 Amps @ 230 V 115V, 60 Hz, 8 Amps
PHYSICAL DIMENSIONS
Height Width Depth Weight
37.4 in. 24.8 in. 60.5 in. 1100 lb.
949 mm 629 mm 1529 mm 499 kg
(1)
Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity.