Lincoln Electric SVM120-A Welder User Manual


 
ACCESSORIES
C-7 C-7
RANGER 10-LX
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CONNECTION OF THE LN-7 TO THE
RANGER 10-LX USING K867 UNIVERSAL
ADAPTER (SEE FIGURE C.4.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
“ELECTRODE” terminal of the welder. Connect the
work cable to the “TO WORK” terminal of the
welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
3. Connect the K867 Universal Adapter to the LN-7
wire feeder and the 14 pin amphenol of the
RANGER 10-LX as indicated in Figure C.4. Make
the proper connections for local or remote control
according Figure C.4 and the following NOTES,
indicated on the figure.
4. Set the welder “polarity” switch to the desired
polarity, either DC (-) or DC (+).
5. Set the “RANGE” switch to the “WIRE FEED” posi-
tion.
6. Place the “IDLER” switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
7. Place the WIRE FEEDER switch in the “WITH CON-
TROL CABLE” position.
8. Adjust wire feed speed at the LN-7 and set the
welding voltage with the output “CONTROL” to a
CV (constant voltage) position at the welder.
NOTE: If optional remote control is used, place the
output control switch in the “CONTROL
REMOTE” position.
FIGURE C.4
RANGER 10-LX/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM
CAUTION
Insulate each unused lead
individually.
Splice the leads and insulate.
A
B