AIR CLEANER: The Kubota diesel engine is equipped
with a dry type air filter. Never apply oil to it. Service
the air cleaner as follows:
1. Remove the dust cup from the bottom of the air
cleaner housing. Clean out any accumulated dust.
2. If dust is sticking to the element, blow compressed
air through the element from the inside out. Turn
the element as you apply air. Air pressure should
be under 686 kPa (7 kgf/cm
2
, 99 psi).
3. If carbon or oil sticks to the element, soak it in
detergent for 15 minutes. Then wash the element
in water, rinse it with clean water and let it air dry.
Check the element for damage before reassem-
bling the air cleaner.
4. Replace the element at least every year or every six
cleanings.
TIGHTENING THE FAN BELT: If the fan belt is loose,
the engine can overheat and the battery lose its
charge. Check tightness by pressing on the belt mid-
way between the pulleys. It should deflect about 7 to
9 mm (0.28 to 0.35 in.) under a load of 10 kgf (22.1
lbs.).
Refer to the Kubota Operator’s Manual for the adjust-
ment procedure.