Lincoln Electric SVM123-A Welding System User Manual


 
A-9
INSTALLATION
IDEALARC DC-1000
A-9
CONNECTION FOR AIR/CARBON ARC
CUTTING OPERATION
THE OUTPUT TERMINALS ARE ENERGIZED AT
ALL TIMES WHEN THE IDEALARC DC-1000 IS
CONNECTED FOR AIR/CARBON ARC CUTTING.
____________________________________________________
1. Set ON/OFF PUSH BUTTON to OFF.
2. Locate and open the access door on the Front
Case Assembly.
3. If necessary, disconnect all wire feeder control
cable connections from the DC-1000 terminal
strip.
4. Remove the leads from the unit by pulling them
through and out of the strain relief box connector
(s).
5. Connect a jumper wire from terminal #2 to termi-
nal #4 on the terminal strip.
6. Set the Welding Mode Switch to the CV(I) position
for air/carbon arc cutting.