Lincoln Electric SVM123-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-23
TROUBLESHOOTING & REPAIR
F-23
15. Test the Output Pilot Relay (4CR)
for operation by removing and
replacing the jumper wire repeat-
edly from terminal #2. See Figure
F.7. This should cause the relay
contacts to open and close. The
contacts can be seen closing and
opening through the clear plastic
relay case or can be heard opening
FIRING BOARD TEST
IDEALARC DC-1000
FIGURE F.8 - Output Pilot Relay 4CR Location
and closing. If the Output Pilot
Relay (4CR) does not close when
energized, check for loose or faulty
wiring. See Wiring Diagram and
Figure F-8.
16. Replace the Firing Board if the
above voltage and control relay
tests are passed. It may be faulty.