F-19
MAIN TRANSFORMER (T1) VOLTAGE TEST
IDEALARC DC-1000
From To Expected VAC
Plug Pin Lead Plug Pin Lead
J5 2 #203 J5 4 #204 75 VAC
J5 7 #205 J5 3 #206 75 VAC
J5 9 #207 J5 8 #208 75 VAC
FIGURE F.5 - Phase Angle Windings Test Points and Firing Board Pin
Location