Lincoln Electric SVM123-A Welding System User Manual


 
C-5
ACCESSORIES
C-5
CONNECTING THE LN-9 WIRE FEEDER
TO THE IDEALARC DC-1000
1. Set the ON/OFF PUSH BUTTON to the OFF pos-
tion.
2. Disconnect AC input power to the IDEALARC DC-
1000.
3. Connect the wire feeder control cable leads to the
DC-1000 terminal strip. See Figure C.4.
4. Connect the wire feeder control cable ground lead
to the frame terminal marked .
5. Extend the wire feeder control cable #21 lead so it
can be connected directly to the work piece.
a. Make a bolted connection using AWG #14
or larger insulated wire.
b. Tape the bolted connection with insulating
tape.
NOTE: An S-16586-X remote voltage sensing work
lead is available for this purpose.
c. Keep the #21 lead elecrically separate
from the work cable circuit and connection.
d. Tape the #21 lead to the work cable for
ease of use.
6. Connect lead #75(A) to #75 on the terminal strip.
7. Connect lead #76(B) to #74 on the terminal strip.
8. Connect lead #77(C) to #73 on the terminal strip.
9. Connect the welding cables as shown in Figure
C.4.
Note: Welding cables must be of proper capacity for
the current and duty cycle for immediate and future
applications.
10. Connect LN-9 wire feeder jumpers on voltage
board as follows: See LN-9 operator’s manual.
a. White jumper on voltage board to pin “S”
b. Blue jumper on voltage board (later mod-
els) or on start board (earlier models) to
pin “B”.
11. Set the DC-1000 output control switch to the
”Output Control Remote” position.
NOTE: The connection diagram shown in figure C-4
shows electrode connected for positive polarity. To
change polarity:
a. Set the IDEALARC DC-1000 ON/OFF
PUSH BUTTON to OFF.
b. Move the electrode cable to the Negative
(-) output terminal.
c. Move the work cable to the Positive (+)
output terminal.
d. Position the positive-negative switch on
the power source to correspond to the
polarity of the electrode cable connection.
e. Refer to LN-9 operating manual for
required polarity connections.
IDEALARC DC-1000
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE C.4 - LN-9 Wire Feeder Connection
to the IDEALARC DC-1000
CAUTION
The IDEALARC DC-1000 must be properly grounded.
____________________________________________________