Lincoln Electric SVM123-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Duty Cycle Amps Volts at Rated Amperes
100% 1000 44
60% 1140 44
55% 1250 44
Mode Current Range Maximum Open Auxiliary
Constant Current 140 to 1250 Amps Circuit Voltage Power
Constant Voltage 140 to 1250 Amps 75 VDC 115 VAC, 8 Amps
Constant Voltage 140 to 625 Amps
(@500 Amp Stud)
IDEALARC DC-1000
A-2
INSTALLATION
TECHNICAL SPECIFICATIONS – IDEALARC DC - 1000
INPUT - THREE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Standard Voltage Input Current at Rated Output
230/460/575 193/96.5/77
Input
Voltage/Frequency
Fuse (Super Lag)
or Breaker Size
Input Ampere Rating on
Nameplate
Type 75C Copper
Wire in Conduit
AWG (IEC) Sizes
230/60
300 193
430/60
150 96.5
575/60
125
77
000 (85mm
2
)
3 (26.7mm
2
)
6 (16mm
2
)
4 (25mm
2
)
6 (16mm
2
)
6 (16mm
2
)
Type 75C Copper
Ground Wire in
Conduit AWG (IEC)
Sizes
Height Width Depth Weight
30.75 in 22.25 in 38.0 in 821 Ibs
(781 mm) (567 mm) (965 mm) (372 kg)
PHYSICAL DIMENSIONS
A-2