Lincoln Electric SVM123-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-48
INSTALLATION
1. Install input contactor using a 7/16”
socket wrench. Attach the four
mounting bolts, nuts, and associat-
ed washers (or tighten the two bot-
tom bolts and nuts, and attach the
top two).
2. Attach leads to contactor interlock.
Connect quick connects on leads
#211 and #212. See Figure F.21.
3. Attach leads from contactor coil.
Attach any cable ties and/or har-
ness looms cut at removal. Attach
lead #257 at secondary thermostat.
See Figure F.20.
4. Using a 11/16” wrench, attach
leads L1, L2, L3 and output power
leads to 1CR contactor. See Figure
F.19.
NOTE: Ensure all leads are connected
correctly. See Wiring Diagram.
IDEALARC DC-1000
F-48
INPUT CONTACTOR (1CR) CLEANING AND/OR REPLACEMENT