Dukane 9001:2000 Welder User Manual


 
100
Dukane Manual Part No. 40356601
DPC
II Plus and EZ Welder System Users Manual
To erase all the stored setups, move the cursor from
ERASE CURRENT SETUP (see Figure 911) to
down to ERASE ALL SETUPS and press ENTER. A
confirmation message is displayed. Move the cur-
sor down to YES as shown in Figure 914. Press
the ENTER key to delete the setup files.
ERASE ALL SETUPS
NO
YES
A progress message (see Figure 915) appears for
about 8 seconds. When the process is complete,
the display returns to the Process Setup menu as
shown in Figure 92
ERASING ALL SETUPS
IN PROCESS...
.
Part Count
The parts count option (see Figure 93) offers three
options. The three choices are to reset the counter,
count suspect/bad parts and preset the counter as
shown in Figure 916.
PART COUNT
RESET PART COUNT
COUNT SUS/BAD PART
PRESET PART COUNT
The count replaces the - - - in the upper left of the
operate screen (see Figures 73. 74, 731 and 753).
Reset Part Count
This function resets the parts counter back to zero.
With the cursor at the reset function, press the
ENTER key. The confirmation screen shown in
Figure 917 is displayed next.
RESET PART COUNT
NO
YES
Use the decrement key to move the cursor down
one line to YES and press the ENTER key. The
counter will be reset and the menu returns to the
part count selection menu shown in Figure 916.
Count Suspect/Bad Part
The second option controls the suspect/bad part
counter. The counter can be set to count all parts or
only the good parts. To configure the counter, move
the cursor down to COUNT SUS/BAD PART (see
Figure 916) and press ENTER. A confirmation
screen (shown in Figure 918) is then displayed.
COUNT SUS/BAD PART
NO
YES
To count all parts, move the cursor to YES, press
ENTER and the menu returns to the part count se-
lection screen shown in Figure 916. To exclude
bad/suspect parts, move the cursor to NO and press
ENTER. The bad/suspect parts are ignored and only
good parts are counted. The menu returns to the
part count selection screen shown in Figure 916.
Figure 914 Confirm Erase All Setups
Figure 915 Erasing All Setups In Process
Figure 916 Part Count Selection Menu
Figure 918 Confirm Counter Enabled
Figure 917 Confirm Reset Part Count