Dukane 9001:2000 Welder User Manual


 
48
Dukane Manual Part No. 40356601
DPC
II Plus and EZ Welder System Users Manual
Press Control Module
Part No. 1103938
This optional module enables the DPC II Plus to
control a Dukane Model 210, 220 or 410 press or
custom automation. This module is also installed
on a EZ Welder System. The module is
illustrated in Figure 58. The cabling hookup to a
Dukane press system is shown in Figure 38.
Pin No. Type Function Signal Description
1 Input Activation Switch 1 Normally Open (N.O.) dry contact closure to ground
2 Input Activation Switch 2 Normally Open (N.O.) dry contact closure to ground
3 Input Hardware Abort Power In Normally Closed (N.C.) emergency switch contact
4 Input Software Abort Normally Open (N.O.) dry contact closure to ground
5 Ground Internal Ground Internal Ground (Gnd)
6 Ground Internal Ground Internal Ground (Gnd)
7 Ground Internal Ground Internal Ground (Gnd)
8 Input Automation Input Normally Open (N.O.) dry contact closure to ground
9 +22V DC
Hardware Abort Power Out
Normally Closed (N.C.) emergency switch contact
J901
Thruster Cable
Connection
J902 Press
Base Cable
Connector
Press Control
Module
P/N 1103938
1
1
5
9
6
1836
19
Molex
DB9
36Contact
Subminature D
Figure 58 Press Control Module
Table 5
V J902 Press Base Connector Pinout
Figure 59 Press
Connector Pin
Identification