Dukane 9001:2000 Welder User Manual


 
101
Dukane Manual Part No. 40356601
Section 9 Utilities Menu
Preset Part Count
This option allows you to preset a value (maxi-
mum = 60,000) in the counter. Again from the part
count selection menu, move the cursor to the bot-
tom line next to PRESET PART COUNT and press
ENTER. A data entry screen for presetting the value
is displayed. Use the left and right arrow keys to
select the digit position, and the up and down ar-
row keys to increment or decrement the value.
PRESET PART COUNT
_0
The underscore indicates the digit position which
is initially under the rightmost digit. To preset the
counter, press ENTER and you are returned to the
part count selection menu shown in Figure 916.
Status Outputs
The third option in the Utilities Menu (see Figure
93) is Status Outputs. Moving the cursor down
to Status Outputs and pressing the ENTER key dis-
plays the Status Output Selection menu.
This menu option permits you to set the four Iso-
lated Status Outputs as either maintained or pulsed.
The default setting is maintained. If the output is
set to pulsed, the output pulse width is 100 msec.
The status output selection menu is shown in Fig-
ure 920. To change the mode, move the cursor to
PULSED and press ENTER.
STATUS OUTPUTS
MAINTAINED
PULSED
The four outputs controlled by this menu are:
1. Isolated Bad Part on Pin 20
2. Isolated Good Part on Pin 21
3. Isolated Ready on Pin 22
4. Isolated InDwell on Pin 23
For a complete description of each signal, refer
back to Table 5IV.
Cycle Press Off Line
The last option in the Utilities Menu (Figure 93)
is Cycle Press Off Line. To access this option move
the cursor down to the last line and press ENTER.
This subsequent menu is shown in Figure 921.
CYCLE PRESS OFF LINE
YES
NO
This option works only with the palm operate
switches on the press base. When the DPC front
panel status is set OFF LINE, it cannot be triggered
to cycle the press. During testing or fixture setup,
it may be necessary to cycle the press without pro-
ducing an ultrasonic output signal. This menu op-
tion permits cycling the press with the DPC set to
OFF LINE. To enable this menu option, move the
cursor key up one line to YES and press the ENTER
key. The press can now be cycled by pressing both
palm activation switches. without producing an ul-
trasonic output signal. An Automation Input signal
(pin 8 of J902) will not cycle the press with this
menu option with the DPC set to OFF LINE.
Figure 919 Counter Preset Value
Figure 920 Status Output Mode Selection
Figure 921 Cycle Press Selection Menu