is reached, whichever comes first. Press ENTER and
the data entry screen appears as shown in Figure
79. If a Power Output module is installed, then a
Weld Method screen shown in Figure 78 is dis-
played first. Press the
ENTER key to display the weld
time data entry. If a Power Output module is not
installed, there is only one choice and the Weld
Method screen is bypassed. Timed Hand Probe op-
eration requires the weld time to be entered. Use the
Left and Right arrow keys to move to the desired
digit position and the Up and Down arrow keys to
increment or decrement the value. When the desired
value is displayed, press
ENTER for the next menu
until all the required values have been entered.
Timed Hand Probe Energy
If a Power Output module is installed, you can also
choose the Weld By Energy method. From the
Weld Method screen shown in Figure 78, move
the cursor down so it points to Weld By Energy
and press the ENTER key.
To weld using the Energy Method, you first enter
the desired welding energy, This data entry screen
is shown in Figure 710. Enter the desired weld-
ing energy and press ENTER . Now enter the maxi-
mum weld time as shown in Figures 711. Press
ENTER to complete the process. You will return to
the Process Setup menu (Figure 75).
WELD METHOD
WELD BY TIME
WELD BY ENERGY
WELD ENERGY
75 J
MAX WELD TIME
1.000 SEC
WELD TIME
0.500 SEC
Figure 79 Hand Probe Weld Time
Figure 710 Hand Probe Weld Energy
Figure 711 Hand Probe Max Weld Time
Figure 78 Hand Probe Weld Method
NOTE
The flowchart beginning with powerup to the
Process Setup menu (Figure 75) and the Trigger
Method screen (Figure 76) is shown in Figure
65. A portion of the drawing is repeated here.
Only present if
Power Output Module
is installed
TRIGGER METHOD
TIMED PROBE
UNTIMED PROBE
PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES
----- #1 TIME ENERGY
0.000 0
MODE
MODE
MODE
CANCEL
CANCEL
ENTER
Figure 73 and 74
Figure 75
Figure 76