Lincoln Electric SVM150-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-57
F-57
RANGER 250
WARNING
OUTPUT RECTIFIER BRIDGE AND CHOKE
REMOVAL AND REPLACEMENT
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot-
ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).
DESCRIPTION
The following procedure will aid the technician in removing and replacing the output rectifier
bridge and the choke from the Ranger 250.
MATERIALS NEEDED
5/16" Nut driver
3/8" Wrench or socket wrench
1/2" Wrenches (two)
9/16" Wrench
Diagonal cutters
This procedure should take approximately 1 hour to perform.