Lincoln Electric SVM150-A Welder User Manual


 
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode No Load RPM Load RPM
Low Idle 2350 - 2450 N/A
High Idle 3700 - 3750 3350 - 3580
WELDER DC (STICK) OUTPUT (ARC control @ -10)
Mode Selector Output Control Open Circuit Load Volts Load Amps
Switch Volts
Stick (CC) Maximum 74-79 25-30 245-265
WELDER CV (WIRE) OUTPUT (ARC Control @ +10)
Mode Selector Output Control Open Circuit Load Volts Load Amps
Switch Voltage
CV Maximum 56-64 25-30 245-265
CV Minimum 20-28 13-14.5 25-30
TOUCH START TIG (ARC Control @ +10)
Mode Selector Output Control Open Circuit Load Volts Load Amps
Switch Voltage
TIG Maximum 16-19 25-30 245-265
TIG Minimum 16-19 Short Circuit 19-24
AUXILIARY POWER OUTPUT
240 Volt Receptacle 120 Volt Receptacles
Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Voltage Voltage
236-252 216-225 35-39 118-126 110-120 18-22
42 VOLT WIRE FEEDER POWER
Open Circuit Voltage Load Volts Load Amps
42-46 40-44 7.0-9.0
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-68 F-68
RANGER 250