Lincoln Electric SVM150-A Welder User Manual


 
WELDER OPERATION
GENERAL INFORMATION
• Do not touch electrically live parts or elec-
trodes with your skin or wet clothing.
• Do not breathe welding fumes or gases.
• Use ventilation or exhaust to remove weld-
ing from the breathing area.
• Keep flammable material away.
• Wear eye, ear, and body protection.
The Ranger 250 can deliver from 40 to 250 amps of
constant current for DC stick welding or from 20 to 250
amps of constant voltage current for DC semiautomat-
ic wire feed welding. DC TIG welding is possible
across the entire range from 20 to maximum rated out-
put. Output can be adjusted by setting the OUTPUT
control dial and the ARC control dial on the output con-
trol panel to the settings that are best for your selected
welding process.
NOTE: An unstable or unsatisfactory welding arc can
result if welding cables are too long or are coiled on the
machine when welding. See Table A.1 in the
Installation section. Straighten out coiled cables
before welding.
OPERATION
B-7 B-7
RANGER 250
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
WARNING
Onan P216 Kohler CH20 Running Time for
16 hp @ 3600 rpm 12 gallons-hours 12 gallons-hours
gal./hr (liters/hr) gal./hr (liters/hr) Onan/Kohler
Low Idle - No Load
2400 R.P.M. 0.6 (2.3) 0.6 (2.3) 20/20
High Idle - No Load
3700 R.P.M. 0.8 (3.0) 0.8 (3.0) 15/15
DC Weld Output
250 Amps @ 25 Volts 1.7 (6.4) 1.4 (5.3) 7.0/8.6
Auxiliary Power
8,000 Watts 1.8 (6.8) 1.4 (5.3) 6.4/8.6
TABLE B.1 TYPICAL RANGER 250 FUEL CONSUMPTION