Multi-Tech Systems MMV1600 Welder User Manual


 
communicating with Node 3. Node 1 is configured with channels one through eight assigned a destination node of 2
and channels nine through sixteen assigned a destination node of 3. Node 2 has channels one through eight set with a
destination node of 1 which is the local site. Node 3 has channels one through eight set for destination channels nine
through sixteen of node 1. Node 2 passes through all communications between nodes 1 and 3.
The first set of parameters in the following examples are for the local site (node 1), the second set for the remote site 1
(node 2) and the last set for remote site 2 (node 3).
Local Channel Parameters/ Node # 01
STP FLOW ENQ/ PASS PASS DESTDEST LINK
CHN SPD WD BIT PAR CTRL ACK ECHO PACE EIA XON CHN NODE A/B
01 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 01 02 A
02 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 02 02 A
03 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 03 02 A
04 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 04 02 A
05 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 05 02 A
06 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 06 02 A
07 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 07 02 A
08 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 08 02 A
09 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 01 03 A
10 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 02 03 A
11 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 03 03 A
12 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 04 03 A
13 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 05 03 A
14 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 06 03 A
15 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 07 03 A
16 19200 8 1 NONE XON/XOFF OFF OFF OFF OFF OFF 08 03 A
OK
Configuration 3 Local Site Channel Parameters
Local Channel Parameters/ Node 02
STP FLOW ENQ/ PASS PASS DESTDEST LINK
CHN SPD WD BIT PAR CTRL ACK ECHO PACE EIA XON CHN NODE A/B
01 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 01 01 A
02 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 02 01 A
03 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 03 01 A
04 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 04 01 A
05 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 05 01 A
06 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 06 01 A
07 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 07 01 A
08 4800 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 08 01 A
OK
Configuration 3 Remote Site 1 Channel Parameters
Local Channel Parameters/ Node 03
STP FLOW ENQ/ PASS PASS DESTDEST LINK
CHN SPD WD BIT PAR CTRL ACK ECHO PACE EIA XON CHN NODE A/B
01 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 09 01 A
02 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 10 01 A
03 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 11 01 A
04 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 12 01 A
05 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 13 01 A
06 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 14 01 A
07 19200 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 15 01 A
08 4800 8 1 NONE XON/XOFF OFF OFF ON OFF OFF 16 01 A
OK