Multi-Tech Systems MMV1600 Welder User Manual


 
As you change parameters, they will not actually be incorporated into your running system until you execute a
Store New Parameters (&W) command.
Table 4-3. Configuration Procedure
Step Procedure
Async Channels
14 Execute the parameter display command to display the current channel parameter status for your local
MultiMux by entering the following:
ATL (hit Return)
The following will be displayed on your supervisory console for a MultiMux MMV1616:
Local Channel Parameters/ Node # 00
STP FLOW ENQ/ PASS PASS DESTDEST LINK
CHN SPD WD BIT PAR CTRL ACK ECHO PACE EIA XON CHN NODE A/B
01 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 01 01 A
02 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 02 01 A
03 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 03 01 A
04 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 04 01 A
05 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 05 01 A
06 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 06 01 A
07 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 07 01 A
08 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 08 01 A
09 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 09 01 A
10 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 10 01 A
11 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 11 01 A
12 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 12 01 A
13 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 13 01 A
14 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 14 01 A
15 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 15 01 A
16 19200 8 1 NONE CTS OFF OFF OFF OFF OFF 16 01 A
15 Based on the listed conditions for each channel, reconfigure the parameters to match your actual channel
requirements by entering commands as described in Chapter 5.
As you change operational parameters, they will not actually be incorporated into your running system until
you execute a Store New Parameters (&W) command.
Table 4-3. Configuration Procedure
Step Procedure
Voice/Fax Channels
16 To display the current Voice/Fax channel parameters, enter the following:
ATVL (hit Return)
The following will be displayed on your supervisory console for the Voice/Fax channels:
LOCAL VOICE/FAX PARAMETERS CHANNEL 1 LOCAL VOICE/FAX PARAMETERS CHANNEL 2
PARAMETER STATUS PARAMETER STATUS
DESTINATION CHANNEL: 01 DESTINATION CHANNEL: 02
DESTINATION NODE: 02 DESTINATION NODE: 02
LINK A/B/D: A LINK A/B/D: A
DIGITIZING RATE: 16000 DIGITIZING RATE: 16000
OUTPUT LEVEL ATTEN.: 12 OUTPUT LEVEL ATTEN.: 12
INPUT LEVEL GAIN: 03 INPUT LEVEL GAIN: 03
SILENCE SUPPRESSION: 00 SILENCE SUPPRESSION: 00
LOCAL INTERFACE TYPE: FXS LOCAL INTERFACE TYPE: FXS
GROUND/LOOP START (FXS): LOOP GROUND/LOOP START (FXS): LOOP
2 OR 4 WIRE (E&M): 2 WIRE 2 OR 4 WIRE (E&M): 2 WIRE
DIALTONE/WINK (E&M): N/A DIALTONE/WINK (E&M): N/A
WINK TIMER (E&M): N/A WINK TIMER (E&M): N/A
REMOTE INTERFACE TYPE: FXS REMOTE INTERFACE TYPE: FXS
GROUND/LOOP START (FXS): LOOP GROUND/LOOP START (FXS): LOOP
2 OR 4 WIRE (E&M): 2 WIRE 2 OR 4 WIRE (E&M): 2 WIRE
DIALTONE/WINK (E&M): N/A DIALTONE/WINK (E&M): N/A