CONFIGURATION OF PORT A: COMPOSITE LINK
DSU TYPE SPEED CLOCKING LOOPBACK
EXTERNAL 56K INTERNAL OFF
CONFIGURATION OF PORT B: SYNC DATA
PROTOCOL SPEED CLOCKING LOOPBACK
ANY SDLC 56K INTERNAL OFF
List Composite This command lists the status of the link configuration parameters. Link Settings The display
indicates the conditions that affect the link's operation, such as the downline load, flush timer value and the
response #L time setting. The default conditions are: inititate downline load is off, a flush
timer value of 10ms and a response time set to R3.
LOCAL MULTIMUX COMPOSITE SETTINGS
INITIATE CHAN 1-8
DOWNLINE FLUSH RESPONSE
LOAD TIMER TIME
OFF 10MS 3
Status This command sets the baud rate of the status report generated
Report by the #S0 command on the system supervisor console display.
Baud Rate The speed options are as follows:
#RBxxxxx #RB300 : 300 bps
#RB1200 : 1200 bps
#RB2400 : 2400 bps
#RB4800 : 4800 bps
#RB9600 : 9600 bps
#RB19200 : 19200bps
Status This command sets the time interval in hours at which the status
Report Time report generated by the #S0 command is displayed on the system supervisor
console display. The intervals are in hour
#RT0-99 increments from 1 to 99 hours, with #RT0 being the off condition.
Programmable The Programmable Retransmit Timer #RXT command allows Retransmit Timer the
user to set a maximum time limit on when an acknowledgement needs to be received from the remote
MultiMux before the data #RXT block is retransmitted. The timer can be set for link A (#RTXA4)
and link B. The range of the timer is between 4 and 12 seconds. The factory default value is 4 seconds.
Composite Link This command generates a statistics report of the composite link
StatusReport for display on the system supervisor console. The composite link status report can be
displayed for link A (#SA) and link B.The #S report is in the following format:
COMPOSITE STATISTICS
ELAPSED TIME : 00 DAYS 00 HRS 00 MIN.
DATA BLOCKS TRANSMITTED : 0
DATA BLOCKS RETRANSMITS : 0
DATA BLOCKS RECEIVED : 0
RECEIVE BLOCK ERRORS : 0
VOICE/FAX BLOCKS TRANSMITTED : 0
VOICE/FAX BLOCKS RECEIVED : 0
LINK ALARMS : 0
REMOTE DOWNS : 0
LINK UTILIZATION : 0%
RECEIVE FLOW CONTROL TIME : 00 HRS 00 MIN 00 SEC.
AUTOMATIC REPORTING : OFF 19200 BAUD
LED Status This command displays the MultiMux front panel LED Status in the following format:
#SL
THIS IS THE CURRENT STATUS OF THE FRONT PANEL LEDS ON MULTIMUX
# = ON BLANK = OFF X=UNKNOWN
COMPOSITE LINK A COMPOSITE LINK B
RF RT RFRT