Multi-Tech Systems MMV1600 Welder User Manual


 
commands. Whether the second voice/fax channel is used depends on whether one or two instruments (telephone or
fax machine) are connected. The parameters for the remote site can be displayed using the VL (List the Voice/Fax
Channel Parameters) command. The voice/fax channel parameters for the remote site are shown in the Configuration
4 Remote Site Voice/Fax Channel Parameters. The voice/fax channel parameters are described in Chapter 5
Commands of this manual.
LOCAL VOICE/FAX PARAMETERS CHANNEL1 LOCAL VOICE/FAX PARAMTERS CHANNEL 2
PARAMETER STATUS PARAMETER STATUS
DESTINATION CHANNEL: 01 DESTINATION CHANNEL: 02
DESTINATION NODE: 01 DESTINATION NODE: 01
LINK A/B/D: A LINK A/B/D: A
DIGITIZING RATE: 16000 DIGITIZING RATE: 16000
OUTPUT LEVEL ATTEN.: 09 OUTPUT LEVEL ATTEN.: 09
INPUT LEVEL GAIN: 06 INPUT LEVEL GAIN: 06
SILENCE SUPPRESSION: 00 SILENCE SUPPRESSION: 00
LOCAL INTERFACE TYPE: FXS LOCAL INTERFACE TYPE: FXS
GROUND/LOOP START (FXS): LOOP GROUND/LOOP START (FXS): LOOP
2 OR 4 WIRE (E&M): 2 WIRE 2 OR 4 WIRE (E&M): 2 WIRE
DIALTONE/WINK (E&M): N/A DIALTONE/WINK (E&M): N/A
WINK TIMER (E&M) N/A WINK TIMER (E&M) N/A
REMOTE INTERFACE TYPE: FXO REMOTE INTERFACE TYPE: FX0
GROUND/LOOP START (FXS): N/A GROUND/LOOP START (FXS): N/A
2 OR 4 WIRE (E&M): 2 WIRE 2 OR 4 WIRE (E&M): 2 WIRE
DIALTONE/WINK (E&M): N/A DIALTONE/WINK (E&M): N/A
Configuration 4 Remote Site Voice/Fax Channel Parameters