Store New The Store New Parameters command causes the MultiMux to
Parameters store new parameters. Prior to executing the &W command,
changes to MultiMux parameters are temporary and do not
&W affect the units operation until you execute the &W command. The &W command
stores the parameters in nonvolatile memory and will takes affect immediately.
Help The Help commands are designed to give you short explanations
on how to use MultiMux commands. They will be useful if your
H manual is not handy, although the explanations are quite short
H1-H7 in comparison to those in the manual. When a Help command
is executed in conjunction with some other command, the
resulting display will explain options and information for that command. The General
Help command provides information on the other MultiMux Help commands.
The H command menu is as follows:
General Help
1. Each command line must begin with the prefix AT.
2. Each command line may contain any number of commands up to 40 characters total.
3. Most command letters must be followed by a value.
4. For help on specific commands, enter "ATH" followed by the command letters.
5. For additional help menus, enter "ATH" followed by numbers 1-7.
A. Type ATH or ATH0 for General Help.
B. Type ATH1 for channel parameter commands.
C. Type ATH2 to view the DIP switch configuration.
D. Type ATH3 for composite link speed and clocking commands.
E. Type ATH4 for additional composite link commands.
F. Type ATH5 for miscellaneous commands.
G. Type ATH6 for voice/fax channel commands.
H. Type ATH7 for additional voice/fax channel commands.
The H1 menu is as follows:
CHANNEL PARAMETER COMMANDS
B - BAUD RATE SELECTION P - PARITY SELECTION
C - CHANNEL SELECTION R - RESPONSE TIME PRIORITY
DC - DEST. CHANNEL SELECTION SB - STOP BIT SELECTION
DN - DEST. NODE SELECTION SN - LOCAL SOURCE NODE NUMBER
E - LOCAL ECHO SNGA..H - DOWNLINE LOAD SOURCE NODE NUMBER
F - FLOW CONTROL #S - CHANNEL STATISTICS
&F - READ IN FACTORY DEFAULTS &SL - SELECT LOCAL PARAMETERS
L - LIST PARAMETERS &SR - SELECT DOWNLINE LOAD PARAMETERS
ML - LINK USED PER CHANNEL WL - WORD LENGTH SELECTION
THE FOLLOWING EXAMPLE WILL SELECT CHANNEL 1 AND SET ITS BAUD RATE TO 2400 AND
THE WORD LENGTH TO 8 BITS:
ATC1B2400WL8 <ENTER>
FOR HELP ON A SPECIFIC COMMAND, ENTER ATH FOLLOWED BY A COMMAND LETTER
The H2 menu is as follows:
MULTIMUX EIGHT POSITION DIP-SWITCH DEFINITIONS AND CONFIGURATIONS
SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 SWITCH 5 SWITCH 6 SWITCH 7 SWITCH 8
INITIATE DSU DSU 8/16 24/32 REMOTE
DWN TYPE TYPE CHANNEL CHANNEL ACCESS
LINE LINK A LINK B
LOAD
UP = ON INTERNAL INTERNAL 16/32 24/32CHAN ENABLED
DN = OFF EXTERNAL EXTERNAL 8/24 8/16CHAN DISABLED
CURRENT SETTINGS:
DN DN DN DN DN DN DN DN
The H3 menu is as follows:
COMPOSITE LINK CLOCKING AND SPEED COMMANDS
INTERNAL DSU