Conair UGR003/0800 Welding System User Manual


 
UGR003/0900 UCR-150L Robot
OPERATION 4-13
S
ETTING TIMER
VALUES
The robot allows you to set time delays for:
arm movements
part ejection
grip
cycle monitor
options
alarms
Up to 15 different timers can be set and changed while the
robot is in operation, or when the robot is stopped. Timers can
be fine tuned while the robot is running in Automatic.
To view and set the timer settings:
Press the Time button.
The current timer settings display, one at a time,
on the display.
Press the Up and Down buttons to
scroll through the timer settings. The timer set-
ting displays as:
M01
the mold number
Timer Setting
tells which mode the
control is displaying
1ST DOWN DLY.
short description of
timer setting
TIM 00
the timer setting number
00.50
is the set time, in seconds,
to the second decimal place
1
2
Press the Forward button
The cursor displays under the first number to
move the cursor to the next digit on the screen.
Enter the new timer value.
Press the number for the timer value you want to
set. The cursor moves to the next digit automati-
cally.
Press the Enter button.
The control accepts the entries and returns to the
previous display screen.
5
4
3
For the table of timer
settings, see Choosing
Timer Settings, in the
Operation section.