TROUBLESHOOTING 6-5
Symptom
The mold does
not close.
The mold does
not open.
Possible cause
The arm is not in the full
up position, or at the
swing outward end.
The safety interlock is on.
The part verification sig-
nal is not working.
The optional cycle start
signal is not working.
The arm is not in the full
up position, or at the
swing outward end.
The safety interlock is on.
Solution
Check the Arm Up (LS-3) and
Swing Outward End (LS-1)
switches and adjust as needed.
Check the output and wiring.
Check that the part verification
is on. Replace the switch if
necessary.
Check the output and wiring.
Check the Arm Up (LS-3) and
Swing Outward End (LS-1)
switches and adjust as needed.
Check the output and wiring.
The common problems you will see with the mold are that it
will not close or it will not open. You need to check settings
and electrical connections.
T
HE MOLD IS
NOT
WORKING
PROPERLY