Conair UGR003/0800 Welding System User Manual


 
UGR003/0900 UCR-150L Robot
TROUBLESHOOTING 6-7
When the strip is not working properly, it does not move for-
ward or backward. You need to adjust the strip speed control,
replace the valve, or check the air lines.
S
TRIP MOTION
IS NOT
WORKING
Symptom
There is no strip
forward motion.
There is not strip
backward motion.
Solution
Check air supply to the robot.
Check for leaks.
Check strip stroke adjustment
for proper distance.
Adjust the strip forward speed
control; replace as needed.
Check the strip valve and
replace as needed.
Check air lines and seals and
replace as needed.
Check air supply to the robot.
Check for leaks.
Check strip stroke adjustment
for proper distance.
Adjust the strip backward
speed control; replace as need-
ed.
Check the strip valve and
replace as needed.
Check air lines and seals and
replace as needed.
Possible cause
There is no air pressure.
Strip stroke adjustment
set too short.
The strip forward speed
control is shut off.
The strip valve is not
functioning.
The air lines/seals are
damaged or leaking.
There is no air pressure.
Strip stroke adjustment
set too short.
The strip backward speed
control is shut off.
The strip valve is not
functioning.
The air lines/seals are
damaged or leaking.