“C” Function Defaults
Func.
Code
Name /
SRW Display
Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)
Units
Overload level settingC041
OV LVL 001.60A
Sets the overload signal level
between 0% and 200% (from 0 to
two time the rated current of the
inverter)
U
Rated current
for each
inverter model
A
Overload level setting,
2nd motor
C241
2OV LVL 001.60A
Sets the overload signal level
between 0% and 200% (from 0 to
two time the rated current of the
inverter)
U
Rated current
for each
inverter model
A
Frequency arrival setting
for acceleration
C042
ARV ACC 0000.0Hz
Sets the frequency arrival setting
threshold for the output frequency
during acceleration,
range is 0.0 to 400.0 Hz
U
0.0 0.0 Hz
Frequency arrival setting
for deceleration
C043
ARV DEC 0000.0Hz
Sets the frequency arrival setting
threshold for the output frequency
during deceleration,
range is 0.0 to 400.0 Hz
U
0.0 0.0 Hz
PID deviation level settingC044
ARV PID 003.0%
Sets the allowable PID loop error
magnitude (absolute value), SP-PV,
range is 0.0 to 100%
U
3.0 3.0 %
PID FBV function high
limit
C052
PID LtU 0100.0%
When the PV exceeds this value,
the PID loop turns OFF the PID
second stage output, range is 0.0 to
100%
U
100.0 100.0 %
PID FBV function variable
low limit
C053
PID LtL 0000.0%
When the PV goes below this
value, the PID loop turns ON the
PID second stage output, range is
0.0 to 100%
U
0.0 0.0 %
359
Configuring Drive
Parameters
3 59
&RQ¿JXULQJ'ULYH
Parameters